TD-150A Digital Differential Manometer equipment with high performance amplifier and semi-conductor sensor. The wide range covers from vacuum to low pressure. This type is very economically disigned and can be used for all of the applications and also. It is matching sensor technology and low cost.
Alarm : 1 point relay contact
Small Size(75mm), light weight and low cost
Wide temp ranges and high quality
Duraility for ripple and vibrations
AC 220V Power(Option : 110V)
Actural Unit : Measuring Unit, % mode change
0.25% Accuracy and Autozero function
DISPLAY 4 Digit LED
TYPE D TYPE, (Option : BD type)
ACCURACY ¡¾ 0.25%F.S
WORKING PRESSURE 400%F.S
TEMPERATURE -20 ~ 80¡É
HUMIDITY 0 ~ 90% R.H
APPLICATION GAS Air, Gas
SENSOR MATERIAL Silicon Diaphragm
PROCESS CONNECTION 4mm Hose
PRESSURE RANGE Pressure Unit kgf/§², Pa, PSI, mmH2O, mmHg, mbar, %
Gauge Pressure 10,100,500,1000,3000,5000mmH2O..10kgf/§²
Compound Pressure ¡¾5, ¡¾10, ¡¾300, ¡¾500, ¡¾760mmHg
CONTROL OUTPUT Relay Output Contact 1 Point
POWER SUPPLY AC 220V ¡¾10% 60Hz (Option : AC110V , DC 24V)
ACCESSORY Panel Mounting Bracket, 4 ¡¿ 6mm Hose 1.5Meter(Option)
WEIGHT Approximately 480g
CASE MATERIALS ABS
Instrouction for key operating set and method
¡¡
In the setting menu when you pressure value increase pages and press the button increase digit one by one
In the setting menu when you pressure value decrease pages and press the buttondecrease one by one (Gradually)
If you enter setting menu, press the same time or press the synchronous, the setting menu are divided

Setting munu procedure and instruction function
C - S This is relay contact at setting point and normal condition contact point is ON position and reaching setting value if must be OFF
If and will be pressed same time marked C - S at display window and after adjust without key input there is displayed END and finised.
D - T This is pressure difference signal in the differential pressure appear to DISPLAY window to set time, and if will be set from 0(Zero) to 10(Ten), If zero is very fast operating and increase one by one.
Then display speed is lower, If and will be pressed same time. Marked D - T at display window and after without key input. There is displayed END and finished.
D - T
ADJUST
If sensor used long time. There is a some error output.
Then key press 3sec. it automatically adjust zero point and compensated output error deviation.